                                Coffeshopp Roof | 
                            
                            
                                 | 
                                Península de Troia, Portugal | 
                            
                            
                                | 
                                    
                                 | 
                                 | 
                            
                            
                                 | 
                                 | 
                            
                                                            
                                    | Structural typology | 
                                    Membrane Structures | 
                                
                            
                                                            
                                    | Date | 
                                    October, 1998 | 
                                
                            
                                                            
                                
                                    | Scope | 
                                    Detailed design and construction support | 
                                
                            
                            
                                                            
                                    | Architect | 
                                    Fernando Silva | 
                                
                                                        
                            
                            
                                | 
                                    
                                 | 
                                 | 
                            
                        
                    
                 
                
                    The roof of the cafeteria on Troia Island covers a surface area of 800m2. 
The main design requirement for the structure was its adaptation to the surrounding buildings and wooded area. The roofing membrane covers a maximum span of 30.0m.
The structure comprises two steel masts, which are connected to each other by a main cable, and are anchored to the foundation element.
The PVC membrane is anchored at four points: At the two mast heads and at the two ground anchors.